We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
Hemoperfusion Machine
Categories

YSHDF6008S Hemodialysis Machine (On-Line HDF)

Model: YSHDF6008S
YSHDF6008S Hemodialysis Machine - intelligent touch-screen dialysis with On-line HDF/HD/HF, one-key priming/drain, automatic disinfection, Kt/V monitoring for safe, efficient care.
  • ModelYSHDF6008S
  • BrandYSENMED
  • PriceGet Price
  • MOQ1
  • Ship FromFrom Guangzhou, China
  • ShippingAny shipping terms convenient for customers
  • Description Get Price Review(0)

    Features

    Intelligent operation system; Easy operation with visual and audio alarms; Multi-purpose service/maintenance interface; Profiling: sodium concentration and UF curve.

    YSHDF6008S ensures the safety and efficiency during dialysis, provided comfortable dialysis treatment, which can use to: On-line HDF, HD and On-line HF.


    - On-line HDF
    - Adopted closed volume balance chamber, accurate ultrafiltration dehydration control;One-key low speed ultrafiltration: can set low speed UF, low speed UF working time, return to normal UF speed automatically after execution; support isolated UF, can modify the executed time and UF volume based on requirement while isolated UF.
    - One-key dialyzer priming+ function
    Can set priming time, priming dehydration volume which effective use of diffusion and convection mechanism to improve the priming effect of bloodlines and dialyzer and improve the dialysis adequacy.
    - Intelligent automatic disinfection and cleaning procedure
    - It can effectively prevent the deposition of calcium and protein in the pipeline of the machine, unnecessary to use sodium hypochlorite to remove protein which avoids the injury to medical personnel during the use of sodium hypochlorite.
    - One-key drainage function
    Convenient and practical one-key drainage function, automatically remove the waste liquid in the bloodline and dialyzer after dialysis treatment, which prevents waste liquid from spilling on the ground when dismantling the pipeline, effectively keep the treatment site clean and reduce the management and transportation cost of medical waste.
    - Intelligent Haemodialysis device alarm system
    - History record of alarm and disinfection
    - 15 inches LCD touch screen
    - Kt/V evaluation
    - Customized the Sodium and UF profiling parameter setting based on patients' actual treatment situation, which is convenient for clinical personalized treatment, patients will feel more comfortable during dialysis and reduce the incidence of common adverse reactions.
     

    Technical Parameter

    Size &Weight
    Size 380mmx400x1380mm (L*W*H)
    Net Weight approx. 88KG
    Gross Weight approx. around 100KG
    Package Size approx. 650×690×1581mm (L x W x H) 
    Power supply
    AC220V, 50Hz/60Hz, 10A 
    Input power 1500W
    Back-up battery 30 minutes
    Working Condition
    Water input pressure 0.1Mpa~0.6Mpa, 15P.S.I~60P.S.I
    Water input temperature 5℃~30℃
    Working environment temperature 10℃~30℃ at relative humidity ≦70%
    UF rate
    Flow range 0ml/h~4000ml/h
    Resolution ratio 1ml
    Precision ±30ml/h
    Blood pump & substitution pump
    Blood pump flow range 10ml/min~600ml/min (diameter: 8mm or 6mm)
    Substitution pump flow range 10ml/min~300ml/min (diameter 8mm or 6mm)
    Resolution ratio 0.1ml
    Precision ±10ml or 10% of reading
    Heparin pump
    Syringe size 20, 30, 50ml
    Flow range 0ml/h~10ml/h
    Resolution ratio 0.1ml
    Precision ±5%
    Monitoring system &Alarm setup
    Venous pressure -180mmHg ~ +600mmHg, ±10mmHg
    Arterial pressure -380mmHg ~ +400mmHg, ±10mmHg
    TMP -180mmHg ~ +600mmHg, ±20mmHg
    Dialysate temperature preset range 34.0℃~39.0℃
    Dialysate flow Less than 800 ml/min (Adjustable)
    Substitution flow range 0-28 L/H (on line HDF)
    Blood leak detection Photo chromic alarm when erythrocyte specific
     volume is 0.32±0.02 or blood leak volume is
     equal or more than 1ml per liter of dialysate.
    Bubble detection Ultrasonic, Alarm when a single air bubble volume
     is more than 200μl at 200ml/min blood flow
    Conductivity Acoustic-optic
    Disinfection/Sanitize 
    1. Hot disinfection
    Time: 30 minutes; Temperature: about 80℃, at flow rate 500ml/min;
    2. Chemical disinfection 
    Time: 30minutes, Temperature: about 36℃~50℃, at flow rate 500ml/min;
    3. Chemical disinfection with heat 
    Time: 45minutes, Temperature: about 36℃~80℃, at flow rate 50ml/min;
    4. Rinse 
    Time: 10minutes, Temperature: about 37℃, at flow rate 800ml/min;
    Storage Environment 
    Storage temperature should be between 5℃~40℃, at relative humidity ≦80% 
    Function
    HDF, on-line BPM, Bi-cart and 2 pcs endotoxin filters  
     
    Write down your demand below and we will contact you within 24h!
    ver_code
    Review

    ver_code
    1/3
    X